The Bora DHP High Pressure Dryers from Donaldson are designed to efficiently manage compressed air at high inlet pressures of up to 50 bar, even in ambient temperatures as high as 50 ºC. Featuring a sophisticated two-stage heat exchanger, these dryers optimize heat transfer for superior performance and reduced power consumption. With flow capacities ranging from 25 to 5,000 m³/h, the Bora DHP series is ideal for a wide range of industrial applications, ensuring reliable and effective air treatment under demanding conditions. Petrotek is an air dryer supplier in the United Arab Emirates (Dubai, Abu Dhabi, Sharjah, Al Ain, Ras Al Khaimah, Ajman & Fujairah), Oman, Qatar, Saudi Arabia, Bahrain, and Kuwait, offering high-performance solutions tailored to your industrial needs.
Product Features:
Capable of handling compressed air at inlet pressures up to 50 bar.
Operates efficiently in ambient temperatures up to 50 ºC.
Two-stage heat exchanger for enhanced heat transfer in air-to-air and air-refrigerant configurations.
Innovative design lowers power consumption compared to conventional models.
Available in a range of 25 to 5,000 m³/h, accommodating various air treatment needs.
Applications:
Ensures consistent and reliable air drying for pneumatic tools and equipment.
Provides efficient air treatment in high-pressure environments.
Ideal for high-pressure air systems in extraction and processing facilities.
Maintains clean, dry air for production processes and equipment.
Industries:
Automotive
Aerospace
Food and Beverage
Energy
Electronics
Specifications:
Inlet Pressure: Up to 50 bar
Ambient Temperature: Up to 50 ºC
Inlet Temperature: Up to 60 °C
Volume Flows: From 25 to 5,000 m³/h
Model Series: Bora DHP 2700 W - DHP 4200 W and Bora DHP 0025 AX - DHP 2280 AX
Technical Data Sheet:
Air cooled version |
Type | Volume flow m³/h | Volume flow m³/min. | Differential pressure mbar | Cooling air requirement m³/h | Cooling water requirement (15°C) m³/h | Power consumption kW | Power supply | |
DHP 2400 AX | 2430 | 40,5 | 250 | 10800 |
| 4,3 | 3~/400V/50Hz (±10%) |
DHP 3000 AX | 3030 | 50,5 | 250 | 14400 |
| 4,8 | 3-/400V/50Hz (±10%) |
DHP 4000 AX | 4020 | 67 | 250 | 14400 |
| 5,6 | 3~/400V/50Hz (±10%) |
DHP 5000 AX | 5010 | 83,5 | 260 | 14800 |
| 6,4 | 3~/400V/50Hz (±10%) |
DHP 6000 AX | 6060 | 101 | 250 | 22200 |
| 8,4 | 3~/400V/50Hz (±10%) |
Water cooled version |
DHP 2400 WX | 2430 | 40,5 | 250 |
| 0,45 | 3,8 | 3~/400V/50Hz (±10%) |
DHP 3000 WX | 3030 | 50,5 | 250 |
| 0,47 | 3,9 | 3-/400V/50Hz (±10%) |
DHP 3000 WX | 4020 | 67 | 250 |
| 0,56 | 4,65 | 3-/400V/50Hz (±10%) |
DHP 5000 WX | 5010 | 83,5 | 260 |
| 0,67 | 5,5 | 3~/400V/50Hz (±10%) |
DHP 6000 WX | 6060 | 101 | 250 |
| 0,92 | 7,0 | 3-/400V/50Hz (±10%) |